NSN 5985-01-187-4997

Part Details | ELECTRICAL DUMMY LOAD

5985-01-187-4997 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 24687961, 2468796-1, 26647961, 2664796-1, 26647961, 2664796-1, 5985-01-187-4997, 01-187-4997, 5985011874997, 011874997

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 23, 198401-187-499700335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-01-187-4997
Part Number Cage Code Manufacturer
2468796-10R8N4ADVANCED TECHNICAL MATERIALS, INC.DBA A T M
2664796-110001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
2664796-100416VICTOR MICROWAVE, INC.
Technical Data | NSN 5985-01-187-4997
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH5.500 INCHES NOMINAL
BODY WIDTH0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM
BODY HEIGHT0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM
POWER RATING130.000 WATTS AVERAGE
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER60.0
VOLTAGE STANDING WAVE RATIO1.10
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
WAVEGUIDE FLANGE DESIGNATIONUG-1478/U
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS