NSN 5985-01-187-6318

Part Details | ELECTRICAL DUMMY LOAD

5985-01-187-6318 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 3151438, L112AA3, L112AA3, 3151438, L112AA3, 5985-01-187-6318, 01-187-6318, 5985011876318, 011876318

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 23, 198401-187-631800335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-01-187-6318
Part Number Cage Code Manufacturer
31514380R8N4ADVANCED TECHNICAL MATERIALS, INC.DBA A T M
L112AA399313COMMUNICATIONS & POWER INDUSTRIESLLC
L112AA359782COMMUNICATIONS & POWER INDUSTRIESLLC
315143810001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
L112AA366775PREMIER MICROWAVE CORP
Technical Data | NSN 5985-01-187-6318
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH7.000 INCHES NOMINAL
OVERALL WIDTH3.000 INCHES NOMINAL
BODY DIAMETER3.000 INCHES NOMINAL
FREQUENCY RANGE RATING+8.900 TO +9.400 GIGAHERTZ
POWER RATING1.000 KILOWATTS AVERAGE
VOLTAGE STANDING WAVE RATIO1.15
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE+8.900 TO +9.400 GIGAHERTZ
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE15.0 POUNDS PER SQUARE INCH GAGE
WAVEGUIDE FLANGE DESIGNATIONAUG-1358/U
COOLING METHOD FORCED LIQUID
COOLANT CHAMBER PRESSURE100.0 POUNDS PER SQUARE INCH GAGE
INPUT COOLANT TEMP30.0 DEG CELSIUS
COOLING SYSTEM COOLANT FLOW RATE0.3 GALLONS PER MINUTE
OPERATING POSITION HORIZONTAL