NSN 5985-01-197-0548

Part Details | DIRECTIONAL COUPLER

5985-01-197-0548 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.

Alternate Parts: A2916205A, A2916-20-5A, 52.2813.715.15LV, DCS2126, DCS212-6, A2916205A, A2916-20-5A, A2916205A, A2916-20-5A, 5985-01-197-0548, 01-197-0548, 5985011970548, 011970548

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59DEC 18, 198401-197-054800384 ( COUPLER, DIRECTIONAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-01-197-0548
Part Number Cage Code Manufacturer
A2916-20-5A60590AIKEN ADVANCED SYSTEMS INC A DIV OFAMSTAR TECHNICAL PRODUCTS INC AN
52.2813.715.15LVD1901HENSOLDT SENSORS GMBHDIV SEPS
DCS212-650021TECHNICAL RESEARCH ANDMANUFACTURING, INC.
A2916-20-5A50021TECHNICAL RESEARCH ANDMANUFACTURING, INC.
A2916-20-5A51283TECHNICAL SERVICES LABORATORY, INC.DBA TSL-REICO
Technical Data | NSN 5985-01-197-0548
Characteristic Specifications
UNIT TYPEMK ANY ACCEPTABLE
RADIO FREQUENCY RATING12.0 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY1.7 TO 1 AT 12 TO 18 GHZ
DESIGN TYPE UNIDIRECTIONAL
POWER LOSS IN DECIBELS0.8
TERMINAL FITTING NAMEFEMALE SMA CONNECTOR
TERMINAL FITTING CONTROLLING AGENCYMILITARY SPECIFICATIONS PROMULGATED BY MILITARY AGENCIES
TERMINAL FITTING IDENTIFYING NUMBERMIL-C-39012
TERMINAL FITTING USAGE DESIGNWY ANY ACCEPTABLE
OVERALL LENGTH1.000 INCHES NOMINAL
OVERALL WIDTH0.500 INCHES NOMINAL
OVERALL HEIGHT0.375 INCHES NOMINAL