NSN 5985-01-198-2545

Part Details | ELECTRICAL DUMMY LOAD

5985-01-198-2545 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: WG0065, WG-0065, 5985-01-198-2545, 01-198-2545, 5985011982545, 011982545

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 05, 198501-198-254500335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-01-198-2545
Part Number Cage Code Manufacturer
WG-006500929MICROLAB/FXR
Technical Data | NSN 5985-01-198-2545
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH4.700 INCHES NOMINAL
OVERALL HEIGHT2.400 INCHES NOMINAL
OVERALL WIDTH2.400 INCHES NOMINAL
FREQUENCY RANGE RATING+12.400 TO +18.000 GIGAHERTZ
POWER RATING400.000 WATTS AVERAGE AND 1.000 KILOWATTS PEAK
VOLTAGE STANDING WAVE RATIO1.15
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE+12.400 TO +18.000 GIGAHERTZ
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE50.0 POUNDS PER SQUARE INCH GAGE
WAVEGUIDE FLANGE DESIGNATIONUG-419/U
COOLING METHOD SELF-COOLED
OPERATING POSITIONC$B