NSN 5985-01-209-2304

Part Details | ELECTRICAL DUMMY LOAD

5985-01-209-2304 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: B40148811, B4014881-1, B40148811, B4014881-1, 5985-01-209-2304, 01-209-2304, 5985012092304, 012092304

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAY 25, 198501-209-230400335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-01-209-2304
Part Number Cage Code Manufacturer
B4014881-156996DEPARTMENT OF THE ARMY HQUNITED STATES ARMY COMMUNICATIONS
B4014881-100341LEXAN INDUSTRIES, INCDBA STRUTHERS ELECTRONICS
Technical Data | NSN 5985-01-209-2304
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH22.000 INCHES MAXIMUM
OVERALL HEIGHT4.750 INCHES NOMINAL
OVERALL WIDTH5.063 INCHES NOMINAL
FREQUENCY RANGE RATING+7.900 TO +8.400 GIGAHERTZ
POWER RATING3.000 KILOWATTS AVERAGE
VOLTAGE STANDING WAVE RATIO1.10
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE+7.900 TO +8.400 GIGAHERTZ
TERMINATION TYPE WAVEGUIDE FLANGE
WAVEGUIDE FLANGE DESIGNATIONUG-138/U
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS
END ITEM IDENTIFICATION5895-01-121-9558 COMMUNICATIONS TERMINAL