NSN 5985-01-235-6820

Part Details | ELECTRICAL DUMMY LOAD

5985-01-235-6820 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 382, 5985-01-235-6820, 01-235-6820, 5985012356820, 012356820

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 04, 198601-235-682000335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-01-235-6820
Part Number Cage Code Manufacturer
38200443WAVELINE, INCORPORATED
Technical Data | NSN 5985-01-235-6820
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH2.000 INCHES NOMINAL
OVERALL HEIGHT1.000 INCHES NOMINAL
FREQUENCY RANGE RATING+3.950 TO +5.850 GIGAHERTZ
POWER RATING2000.000 WATTS AVERAGE AND 1300.000 KILOWATTS PEAK
VOLTAGE STANDING WAVE RATIO1.10
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE+3.950 TO +5.850 GIGAHERTZ
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE35.0 POUNDS PER SQUARE INCH GAGE
WAVEGUIDE FLANGE DESIGNATIONUG-407/U
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS
END ITEM IDENTIFICATIONTRAINING SET,TACTICAL ELECTRONIC WARFARE AN/MSQ-T13
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT