NSN 5985-01-262-4263

Part Details | ELECTRICAL DUMMY LOAD

5985-01-262-4263 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: S007A8A, S-007A8A, 29121811, 2912181-1, LSH118, LSH-118, LSH118, LSH-118, LSH118, LSH-118, 5985-01-262-4263, 01-262-4263, 5985012624263, 012624263

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 28, 198701-262-426300335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-01-262-4263
Part Number Cage Code Manufacturer
S-007A8A12868BEHLMAN ELECTRONICS, INC.
2912181-110001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
LSH-11854X10RAYTHEON COMPANYDBA RAYTHEON
LSH-11849956RAYTHEON COMPANYDBA RAYTHEON
LSH-1183B150RAYTHEON COMPANYDBA RAYTHEON
Technical Data | NSN 5985-01-262-4263
Characteristic Specifications
POWER RATING3.000 KILOWATTS AVERAGE AND 380.000 KILOWATTS PEAK
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER65.0
VOLTAGE STANDING WAVE RATIO1.10
TERMINATION TYPE WAVEGUIDE FLANGE
COOLING METHOD FORCED LIQUID
COOLANT CHAMBER PRESSURE100.0 POUNDS PER SQUARE INCH GAGE
INPUT COOLANT TEMP40.0 DEG CELSIUS
COOLING SYSTEM COOLANT FLOW RATE2.0 GALLONS PER MINUTE