NSN 5985-01-266-5776

Part Details | ELECTRICAL DUMMY LOAD

5985-01-266-5776 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 10344W150, 1-0344-W1-50, J14WT50, J14WT-50, 5985-01-266-5776, 01-266-5776, 5985012665776, 012665776

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 27, 198701-266-577600335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-01-266-5776
Part Number Cage Code Manufacturer
1-0344-W1-5014949TROMPETER ELECTRONICS, INC.
J14WT-5014949TROMPETER ELECTRONICS, INC.
Technical Data | NSN 5985-01-266-5776
Characteristic Specifications
OVERALL LENGTH2.867 INCHES NOMINAL
OVERALL HEIGHT0.590 INCHES MINIMUM AND 0.610 INCHES MAXIMUM
OVERALL WIDTH1.657 INCHES MINIMUM AND 1.717 INCHES MAXIMUM
IMPEDANCE RATING IN OHMS50.0 NOMINAL
TERMINATION TYPE CONNECTION COAXIAL
COAXIAL CONNECTOR SERIES DESIGNATION BNC
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS
SPECIAL FEATURESWRENCH CRIMP
CRITICALITY CODE JUSTIFICATIONACYW
RF CONNECTOR CHANGING FEATURE NOT INCLUDED
FRAGILITY FACTOR MODERATELY RUGGED
SUPPLEMENTARY FEATURESNICKEL PLATED; TWO0.156 IN. DIA MTG HOLES