NSN 5985-01-306-9796

Part Details | DIRECTIONAL COUPLER

5985-01-306-9796 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.

Alternate Parts: CRM1050057702, CRM-10-500/57702, 725016A03916, 725016A0391-6, 5985-01-306-9796, 01-306-9796, 5985013069796, 013069796

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59SEP 03, 198901-306-979600384 ( COUPLER, DIRECTIONAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-01-306-9796
Part Number Cage Code Manufacturer
CRM-10-500/5770212457MERRIMAC INDUSTRIES, INC.
725016A0391-687990QUARTERMASTER GENERAL
Technical Data | NSN 5985-01-306-9796
Characteristic Specifications
UNIT TYPEML ANY ACCEPTABLE
RADIO FREQUENCY RATING500.0 MEGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY1.3 TO 1 MAXIMUM IN 50 OHM SYSTEM LOOKING INTO ALL PORTS
DESIGN TYPE BIDIRECTIONAL
TERMINAL FITTING NAMESMA FEMALE CONNECTOR ON ALL THREE PORTS
OVERALL LENGTH2.170 INCHES NOMINAL
OVERALL WIDTH0.560 INCHES MAXIMUM
OVERALL HEIGHT1.470 INCHES MAXIMUM
SPECIAL FEATURESTWO 0.16 IN DIA MOUNTING HOLES TWO MOUNTING PLACES,EACH END