NSN 5985-01-323-1729

Part Details | ELECTRICAL DUMMY LOAD

5985-01-323-1729 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 1683631, 168363-1, 5985-01-323-1729, 01-323-1729, 5985013231729, 013231729

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 23, 199001-323-172900335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-01-323-1729
Part Number Cage Code Manufacturer
168363-124930HARRIS CORPORATIONDBA ELECTRONIC SYSTEMS, RADAR
Technical Data | NSN 5985-01-323-1729
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH13.000 INCHES NOMINAL
OVERALL WIDTH5.750 INCHES NOMINAL
BODY DIAMETER4.000 INCHES NOMINAL
FREQUENCY RANGE RATING+2.900 TO +3.100 GIGAHERTZ
POWER RATING3.200 MEGAWATTS PEAK AND 25.000 KILOWATTS AVERAGE
VOLTAGE STANDING WAVE RATIOB1.10$$B1.30
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE+2.900 TO +3.100 GIGAHERTZ AND +2.400 TO +3.200 GIGAHERTZ
TERMINATION TYPE WAVEGUIDE FLANGE
COOLING METHOD FORCED LIQUID
COOLANT CHAMBER PRESSURE150.0 POUNDS PER SQUARE INCH GAGE
INPUT COOLANT TEMP55.0 DEG CELSIUS
COOLING SYSTEM COOLANT FLOW RATE5.0 GALLONS PER MINUTE
OPERATING POSITION ALL POSITIONS
END ITEM IDENTIFICATIONOT-141/SPS-48E,TRANSMITTER GROUP