NSN 5985-01-354-0695

Part Details | ELECTRICAL DUMMY LOAD

5985-01-354-0695 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 8720891, 872089-1, WBA45, WB-A45, 5985-01-354-0695, 01-354-0695, 5985013540695, 013540695

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59FEB 22, 199201-354-069500335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-01-354-0695
Part Number Cage Code Manufacturer
872089-120418DRS SUSTAINMENT SYSTEMS, INC.Use CAGE Code 98255 for cataloging
WB-A4500929MICROLAB/FXR
Technical Data | NSN 5985-01-354-0695
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH2.281 INCHES MAXIMUM
OVERALL HEIGHT1.630 INCHES NOMINAL
OVERALL WIDTH1.630 INCHES NOMINAL
FREQUENCY RANGE RATING+9.000 TO +9.600 GIGAHERTZ
POWER RATING140.000 WATTS PEAK AND 140.000 KILOWATTS PEAK
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER77.0
VOLTAGE STANDING WAVE RATIO1.15
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE30.0 POUNDS PER SQUARE INCH GAGE
WAVEGUIDE FLANGE DESIGNATIONWR-90
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS
SPECIAL FEATURESDUMMY LOAD,HIGH POWER; MAXIMUM OPERATING AMBIENT TEMPERATURE,77 DEG.C.
END ITEM IDENTIFICATIONAWADS RADAR B,AN/APQ-175