NSN 5985-01-409-0663

Part Details | DIRECTIONAL COUPLER

5985-01-409-0663 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.

Alternate Parts: 6194180, 6194-180, 6194180, 6194-180, 6194180, 6194-180, ES819801, ES8198-01, 5985-01-409-0663, 01-409-0663, 5985014090663, 014090663

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAR 03, 199501-409-066300384 ( COUPLER, DIRECTIONAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-01-409-0663
Part Number Cage Code Manufacturer
6194-18009992ARRA INC
6194-18098255DRS SUSTAINMENT SYSTEMS, INC.
6194-18020418DRS SUSTAINMENT SYSTEMS, INC.Use CAGE Code 98255 for cataloging
ES8198-0120418DRS SUSTAINMENT SYSTEMS, INC.Use CAGE Code 98255 for cataloging
Technical Data | NSN 5985-01-409-0663
Characteristic Specifications
UNIT TYPEMK ANY ACCEPTABLE
RADIO FREQUENCY RATING8.0 GIGAHERTZ MINIMUM AND 12.4 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY1.80 TO 1 AT 8 TO 12.4 GHZ
DESIGN TYPE BIDIRECTIONAL
TERMINAL FITTING NAMESMA FEMALE COUPLING
OVERALL LENGTH2.010 INCHES NOMINAL
OVERALL WIDTH1.250 INCHES NOMINAL
OVERALL HEIGHT0.380 INCHES NOMINAL
SPECIAL FEATURESUNIT SUPPLIED WITH PROTECTIVE DUST COVERS ON INTERFACE CONNECTORS; ISOLATION 15 DB MIN; 1.0 DB MAX INSERTION LOSS