NSN 5985-01-430-5025

Part Details | DIRECTIONAL COUPLER

5985-01-430-5025 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.

Alternate Parts: 587R428H01, 5985-01-430-5025, 01-430-5025, 5985014305025, 014305025

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59APR 30, 199601-430-502500384 ( COUPLER, DIRECTIONAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-01-430-5025
Part Number Cage Code Manufacturer
587R428H0197942NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS
Technical Data | NSN 5985-01-430-5025
Characteristic Specifications
UNIT TYPEMM ANY ACCEPTABLE
RADIO FREQUENCY RATING99.0 GIGAHERTZ MINIMUM AND 141.0 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY1 TO 1 AT 1
TERMINAL FITTING NAMECHOKE FLANGE
TERMINAL FITTING CONTROLLING AGENCYM39922/59-008
OVERALL DEPTH3.045 INCHES NOMINAL
SPECIAL FEATURESMICROWAVE; INTEGRAL ELECTRONIC DRIVER; POWER SUPPLY, 28VDC NOMINAL; INSERTION LOSS, 0.20DB MAX. IN COUPLED STATE AND 0.75DB IN UNCOUPLED STATE; COUPLING, POWER OUTPUT, PORT 4, -12DB P/M0.5DB DOWN FROM PORT 1 IN COUPLING STATE; POWER OUTPUT, PORT 3, -15DB P/M0.5DB DOWN FROM PORT 1 IN COUPLING STATE;COUPLING FLATNESS P/M 0.5DB; ISOLATION, BETWEEN PORT 1 AND PORTS 3 AND 4, 35DB MIN. IN COUPLING STATE; DIRECTIVITY, -15DB MIN.; SWITCHING TIME, 60 MICROSECONDS MAX.; SHOCK, VIBRATION, FUNGUS RESISTANT; OPERATING LIFE, 200,000 MIN.