NSN 5985-01-478-1118

Part Details | ELECTRICAL DUMMY LOAD

5985-01-478-1118 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 9820523, 98-20523, E20523000, E20523-000, 5985-01-478-1118, 01-478-1118, 5985014781118, 014781118

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 30, 200001-478-111800335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-01-478-1118
Part Number Cage Code Manufacturer
98-205238M906ETM--ELECTROMATIC, INC.
E20523-0008M906ETM--ELECTROMATIC, INC.
Technical Data | NSN 5985-01-478-1118
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
FREQUENCY RANGE RATING+14.000 TO +14.200 GIGAHERTZ
POWER RATING30.000 KILOWATTS PEAK AND 2.000 KILOWATTS AVERAGE
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWERBM40.0$$B65.0
VOLTAGE STANDING WAVE RATIO1.15
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE5.0 POUNDS PER SQUARE INCH GAGE
COOLING METHOD FORCED AIR
OPERATING POSITION ALL POSITIONS
END ITEM IDENTIFICATIONRADAR THREAT EMITTER AN/MST-T1