NSN 5985-01-502-7692

Part Details | ELECTRICAL DUMMY LOAD

5985-01-502-7692 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: TRM2445F0SMA02, TRM-2445-F0-SMA-02, GT817AR1J, 5985-01-502-7692, 01-502-7692, 5985015027692, 015027692

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59NOV 20, 200201-502-769200335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

COAXIAL MOUNTED

Cross Reference | NSN 5985-01-502-7692
Part Number Cage Code Manufacturer
TRM-2445-F0-SMA-0234078CINCH CONNECTIVITY SOLUTIONS, INC.
GT817AR1J26512NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS
Technical Data | NSN 5985-01-502-7692
Characteristic Specifications
STYLE DESIGNATOR COAXIAL MOUNTED
OVERALL LENGTH0.780 INCHES NOMINAL
OVERALL DIAMETER0.320 INCHES NOMINAL
FREQUENCY RANGE RATING+0.000 TO +18.000 GIGAHERTZ
POWER RATING0.500 WATTS PEAK
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWERBM54.0$$B125.0
IMPEDANCE RATING IN OHMS50.0 NOMINAL
VOLTAGE STANDING WAVE RATIO1.05
TERMINATION TYPE CONNECTOR
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS
END ITEM IDENTIFICATIONCEC PROVISION; WSD: AIRCRAFT, HAWKEYE E-2C