NSN 5985-01-527-4017

Part Details | ELECTRICAL DUMMY LOAD

5985-01-527-4017 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 68493671, 6849367-1, 68493671, 6849367-1, 68493671, 6849367-1, 68493671, 6849367-1, 5985-01-527-4017, 01-527-4017, 5985015274017, 015274017

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59FEB 01, 200501-527-401700335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

WAVEGUIDE MOUNTED

Cross Reference | NSN 5985-01-527-4017
Part Number Cage Code Manufacturer
6849367-153711NAVAL SEA SYSTEMS COMMAND
6849367-154X10RAYTHEON COMPANYDBA RAYTHEON
6849367-149956RAYTHEON COMPANYDBA RAYTHEON
6849367-13B150RAYTHEON COMPANYDBA RAYTHEON
Technical Data | NSN 5985-01-527-4017
Characteristic Specifications
STYLE DESIGNATOR WAVEGUIDE MOUNTED
OVERALL LENGTH5.750 INCHES MAXIMUM
BODY WIDTH3.000 INCHES NOMINAL
BODY HEIGHT4.240 INCHES NOMINAL
POWER RATING600.000 WATTS AVERAGE
IMPEDANCE RATING IN OHMS50.0 NOMINAL
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE35.0 POUNDS PER SQUARE INCH GAGE
COOLING METHOD FORCED LIQUID
COOLANT CHAMBER PRESSURE35.0 POUNDS PER SQUARE INCH GAGE
INPUT COOLANT TEMP41.0 DEG CELSIUS
COOLING SYSTEM COOLANT FLOW RATE1.0 GALLONS PER MINUTE
SPECIFICATION/STANDARD DATA53711 - MIL-D-3954 GOVERNMENT SPECIFICATION