NSN 5998-01-318-4088

Part Details | PRINTED WIRING BOARD

5998-01-318-4088 An insulating panel upon which completely processed electrical conductor paths are deposited, etched, or printed in various patterns to provide or complete a circuit between two or more points. It may provide contacts for plug-in connecting facilities. It may be designed for panel or chassis mounting, or for insertion into a CONNECTOR, RECEPTACLE, ELECTRICAL. For items containing printed electronic components, see PRINTED CIRCUIT BOARD. For items containing separately manufactured electronic components, see CIRCUIT CARD ASSEMBLY. For items consisting only of electrical conductor paths and two or more connectors, see BACKPLANE ASSEMBLY.

Alternate Parts: 5623260, 5998-01-318-4088, 01-318-4088, 5998013184088, 013184088

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59APR 18, 199001-318-408861737 ( PRINTED WIRING BOARD )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5998-01-318-4088
Part Number Cage Code Manufacturer
562326053711NAVAL SEA SYSTEMS COMMAND
Technical Data | NSN 5998-01-318-4088
Characteristic Specifications
PART NAME ASSIGNED BY CONTROLLING AGENCYVOLTAGE DIVIDER A9A1
OVERALL LENGTH4.920 INCHES NOMINAL
OVERALL WIDTH3.750 INCHES NOMINAL
SPECIAL FEATURESMATERIAL COPPER CLAD LAMINATED PLASTIC SHEET PER MIL-P-13949/4,TYPE GFN0620C1/C1 B2B; FINISH TIN LEAD PER MIL-STD-275; 117 0.032 IN. DIA MIN TO 0.038 IN. DIA MAX THRU HOLES; 10 0.041 IN. DIA MIN TO 0.047 IN. DIA MAX THRU HOLES; 48 0.056 IN. DIA MIN TO 0.062 IN. DIA MAX THRU HOLES; 6 0.119 IN. DIA MIN TO 0.123 IN. DIA MAX THRU HOLES; 4 0.155 IN. DIA MIN TO 0.161 IN. DIA MAX THRU HOLES; 6 0.091 IN. DIA MIN TO 0.097 IN. DIA MAX THRU HOLES