NSN 5999-01-080-6486
Part Details | DELAY LINE
5999-01-080-6486 An item which provides a predetermined delay to an electrical pulse, while maintaining substantially the same waveform. The delay is obtained by means of a real or artificial transmission line or equivalent device. The equivalent device may be acoustic, distributive, lumped constant, magnetic solid state, or surface acoustical wave type. See also ATTENUATOR, (as modified); TRANSFORMER, (as modified); and OSCILLATOR, PULSE DELAY.
Alternate Parts: TZB3010, TZB30-10, 5999-01-080-6486, 01-080-6486, 5999010806486, 010806486
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 29, 1979 | 01-080-6486 | 06373 ( DELAY LINE ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
FOUR POSITION RECTANGULAR
Cross Reference | NSN 5999-01-080-6486
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| TZB30-10 | 16714 | RHOMBUS INDUSTRIES INC |
Technical Data | NSN 5999-01-080-6486
| Characteristic | Specifications |
|---|---|
| SIGNAL DELAY METHOD | LUMPED CONSTANT |
| DELAY TIME VARIATION METHOD | TAPPED |
| INDIVIDUAL SECTION QUANTITY | 1 |
| SECTION DELAY TIME | EFACN40.000 NANOSECONDS |
| SEGMENT QUANTITY PER SECTION | 10 SINGLE SECTION |
| SEGMENT DELAY TIME | EFACNAQ4.000 NANOSECONDS |
| OPERATING TEMP RANGE | -55.0 TO +125.0 DEG CELSIUS |
| INPUT IMPEDANCE RATING | 50.000 OHMS |
| OUTPUT IMPEDANCE RATING | 50.000 OHMS |
| ATTENUATION IN DECIBELS | 5.000 |
| VOLTAGE RATING | 50.000 VOLTS NOMINAL |
| PULSE RISE TIME RATING | 6.5 NANOSECONDS |
| BODY STYLE | RECTANGULAR |
| BODY LENGTH | 0.525 INCHES MAXIMUM |
| BODY WIDTH | 0.225 INCHES NOMINAL |
| MATERIAL AND LOCATION | AAAAAAAAB ANY ACCEPTABLE |
| SURFACE TREATMENT AND LOCATION | AAAAAAAAB ANY ACCEPTABLE |
| TERMINAL TYPE AND QUANTITY | 12 PIN |
| MOUNTING FACILITY | PIN |
| MOUNTING FACILITY QUANTITY | 12 |
| MOUNTING PROVISION ARRANGEMENT STYLE | FOUR POSITION RECTANGULAR |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.041 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.100 INCHES NOMINAL |