NSN 5999-01-201-2450
Part Details | DELAY LINE
5999-01-201-2450 An item which provides a predetermined delay to an electrical pulse, while maintaining substantially the same waveform. The delay is obtained by means of a real or artificial transmission line or equivalent device. The equivalent device may be acoustic, distributive, lumped constant, magnetic solid state, or surface acoustical wave type. See also ATTENUATOR, (as modified); TRANSFORMER, (as modified); and OSCILLATOR, PULSE DELAY.
Alternate Parts: TTLDM150MT, TTLDM-150MT, DSP1127, DSP-1127, SMA98489810, SM-A-984898-10, 5999-01-201-2450, 01-201-2450, 5999012012450, 012012450
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | FEB 14, 1985 | 01-201-2450 | 06373 ( DELAY LINE ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
FOUR POSITION RECTANGULAR
Cross Reference | NSN 5999-01-201-2450
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| TTLDM-150MT | 32440 | CORNUCOPIA TOOL & PLASTICS INC.DIV ENGINEERED COMPONENTS COMPANY |
| DSP-1127 | 16714 | RHOMBUS INDUSTRIES INC |
| SM-A-984898-10 | 80063 | US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS |
Technical Data | NSN 5999-01-201-2450
| Characteristic | Specifications |
|---|---|
| SIGNAL DELAY METHOD | LUMPED CONSTANT |
| DELAY TIME VARIATION METHOD | TAPPED |
| INDIVIDUAL SECTION QUANTITY | 1 |
| SECTION DELAY TIME | EFACN150.000 NANOSECONDS |
| SEGMENT QUANTITY PER SECTION | 5 SINGLE SECTION |
| SEGMENT DELAY TIME | EFACNAQ30.000 NANOSECONDS |
| OPERATING TEMP RANGE | -55.0 TO +125.0 DEG CELSIUS |
| PULSE RISE TIME RATING | 4.0 NANOSECONDS |
| BODY STYLE | RECTANGULAR |
| BODY LENGTH | 0.810 INCHES MAXIMUM |
| BODY WIDTH | 0.510 INCHES MAXIMUM |
| BODY DEPTH | 0.165 INCHES MAXIMUM |
| MATERIAL AND LOCATION | PCP000AZM PLASTIC, EPOXY |
| TERMINAL TYPE AND QUANTITY | 14 PIN |
| MOUNTING FACILITY | TERMINAL |
| MOUNTING FACILITY QUANTITY | 14 |
| MOUNTING PROVISION ARRANGEMENT STYLE | FOUR POSITION RECTANGULAR |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.600 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.300 INCHES NOMINAL |