NSN 6110-01-415-2313
Part Details | ELECTRICAL MOTOR THERMAL-OVERLOAD PROTECTOR
6110-01-415-2313 A protective device specifically designed to prevent damage to an electrical motor due to failure of the motor to start, severe overloading of short duration, too frequent starting, high ambient temperature, high or low circuit voltages, failure of ventilation or any combination thereof. It is designed to be either automatically or manually reset. Excludes CIRCUIT BREAKEY; SWITCH (1), THERMOSTATIC; HEATER, THERMAL RELEASE; and RELAY (1), THERMAL.
Alternate Parts: SK3627 ITEM 9, SK-3627 ITEM 9, DE252, DE2-52, 6110-01-415-2313, 01-415-2313, 6110014152313, 014152313
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JUN 22, 1995 | 01-415-2313 | 60869 ( PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-415-2313
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| SK-3627 ITEM 9 | 30793 | INSINGER MACHINE COMPANY, THE |
| DE2-52 | 30793 | INSINGER MACHINE COMPANY, THE |
Technical Data | NSN 6110-01-415-2313
| Characteristic | Specifications |
|---|---|
| CURRENT TYPE | AC |
| CURRENT RATING IN AMPS | 2.0 |
| VOLTAGE RATING | 380.0 VOLTS MINIMUM AND 480.0 VOLTS MAXIMUM |
| FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| PHASE | THREE |
| END ITEM DESIGN CONTROL ACTIVITY | 30793 |
| END ITEM YEAR(S) | 1994 |
| END ITEM IDENTIFICATION DESIGNATOR | CONTROL BOX |