NSN 6110-01-464-2463
Part Details | MOTOR CONTROLLER
6110-01-464-2463 A device which, in addition to starting and stopping a motor, performs one or more of the following functions: reverses the rotation, selects the speed, and/or regulates the speed of a motor. Includes items of this type whose design provides means for operation with a rheostat or speed regulator which may be integral or included. Items such as drum switches may be included. See also STARTER, MOTOR.
Alternate Parts: DC271U, DC2-71U, DC271U, DC2-71U, 6110-01-464-2463, 01-464-2463, 6110014642463, 014642463
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | APR 22, 1999 | 01-464-2463 | 00904 ( CONTROLLER, MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-464-2463
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| DC2-71U | 50380 | RELIANCE ELECTRIC |
| DC2-71U | 71956 | RELIANCE ELECTRIC COMPANYDBA RELIANCE & DODGE BRANDS |
Technical Data | NSN 6110-01-464-2463
| Characteristic | Specifications |
|---|---|
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| SIZE DESIGNATOR | 12 |
| AC VOLTAGE RATING | 115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL |
| FREQUENCY RATING | 48.0 HERTZ MINIMUM AND 62.0 HERTZ MAXIMUM |
| PHASE | SINGLE |
| FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
| FUSE CURRENT RATING IN AMPS | 25.0 |
| CONTROL TYPE | LOCAL |
| ACTUATION METHOD | MANUAL |
| DUTY CYCLE | CONTINUOUS |
| AMBIENT TEMP | 0.0 DEG CELSIUS AND 40.0 DEG CELSIUS |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | INDUSTRIAL USE-NEMA TYPE 12 |
| OVERALL WIDTH | 5.000 INCHES NOMINAL |
| OVERALL LENGTH | 5.500 INCHES NOMINAL |
| OVERALL HEIGHT | 10.125 INCHES NOMINAL |