NSN 6110-01-502-8714
Part Details | MOTOR CONTROLLER
6110-01-502-8714 A device which, in addition to starting and stopping a motor, performs one or more of the following functions: reverses the rotation, selects the speed, and/or regulates the speed of a motor. Includes items of this type whose design provides means for operation with a rheostat or speed regulator which may be integral or included. Items such as drum switches may be included. See also STARTER, MOTOR.
Alternate Parts: 423990031, 4239-90031, D5255901, D-52559-01, 6110-01-502-8714, 01-502-8714, 6110015028714, 015028714
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | NOV 22, 2002 | 01-502-8714 | 00904 ( CONTROLLER, MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-502-8714
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 4239-90031 | 10023 | CHROMALOX, INC.DIV CHROMALOX |
| D-52559-01 | 10023 | CHROMALOX, INC.DIV CHROMALOX |
Technical Data | NSN 6110-01-502-8714
| Characteristic | Specifications |
|---|---|
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| OPERATING VOLTAGE CHARACTERISTIC | FULL |
| PHASE | THREE |
| FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
| FUSE ACCOMMODATION QUANTITY | 11 |
| FUSE CURRENT RATING IN AMPS | B100.0$$B2.0 |
| CONTROL TYPE | REMOTE |
| ACTUATION METHOD | MAGNETIC |
| ACTUATOR VOLTAGE | 440.0 AC |
| FREQUENCY IN HERTZ | 60.0 |
| PERFORMANCE TYPE | AUTOMATIC AND MANUAL |
| DUTY CYCLE | CONTINUOUS |
| AMBIENT TEMP | 50.0 DEG CELSIUS |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF |
| INCLOSURE FEATURE | DUST TIGHT |
| SPECIAL FEATURES | DESIGNED IN ACCORDANCE WITH MIL-C-2212 |
| END ITEM IDENTIFICATION | CONTROL, F.O. TRANSFER HEATER |