NSN 6110-01-527-4668
Part Details | MOTOR CONTROLLER
6110-01-527-4668 A device which, in addition to starting and stopping a motor, performs one or more of the following functions: reverses the rotation, selects the speed, and/or regulates the speed of a motor. Includes items of this type whose design provides means for operation with a rheostat or speed regulator which may be integral or included. Items such as drum switches may be included. See also STARTER, MOTOR.
Alternate Parts: 6962CMS1063, 6962CMS1063, 7598776 REV A IT 1, 7598776 REV A, 7598776 ITEM 1, 6110-01-527-4668, 01-527-4668, 6110015274668, 015274668
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | FEB 03, 2005 | 01-527-4668 | 00904 ( CONTROLLER, MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-527-4668
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 6962CMS1063 | 6W438 | CALIFORNIA MARINE SUPPLY, INC |
| 6962CMS1063 | 27192 | DRS POWER & CONTROL TECHNOLOGIES,INC |
| 7598776 REV A IT 1 | 53711 | NAVAL SEA SYSTEMS COMMAND |
| 7598776 REV A | 53711 | NAVAL SEA SYSTEMS COMMAND |
| 7598776 ITEM 1 | 53711 | NAVAL SEA SYSTEMS COMMAND |
Technical Data | NSN 6110-01-527-4668
| Characteristic | Specifications |
|---|---|
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| SIZE DESIGNATOR | 1 |
| OPERATING VOLTAGE CHARACTERISTIC | B$C |
| VOLTAGE REDUCTION METHOD | AUTOTRANSFORMER |
| FULL VOLTAGE RESTORING METHOD | CURRENT LIMIT ACCELERATION |
| AC VOLTAGE RATING | 450.0 VOLTS NOMINAL |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| PHASE | THREE |
| AMP SIZE RATING | 27.0 |
| HORSEPOWER RATING | 0.500 |
| FEATURES PROVIDED | ACCESSORY LOCATION INTERNAL AND CIRCUIT PROTECTION FUSE |
| FUSE ACCOMMODATION QUANTITY | 13 |
| FUSE CURRENT RATING IN AMPS | B10.0$$B17.0 |
| CONTROL TYPE | K$DAAY |
| ACTUATION METHOD | MAGNETIC |
| ACTUATOR VOLTAGE | 450.0 AC |
| FREQUENCY IN HERTZ | 60.0 |
| LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE RELEASE AND SHORT CIRCUIT AND UNDERVOLTAGE |
| DUTY CYCLE | CONTINUOUS AND VARIABLE |
| AMBIENT TEMP | 50.0 DEG CELSIUS |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |
| INCLOSURE FEATURE | DRIPPROOF AND EXPLOSION PROOF AND MOISTURE PROOF AND SPRAY TIGHT |
| SPECIAL FEATURES | 13 CONTROLLERS REQUIRED FOR FULL OPERATION OF ALL FAN COIL SYSTEMS;LOW VOLTAGE RELEASE |
| END ITEM IDENTIFICATION | AER 28/00, LHD 4 BOXER;FAN COIL UNIT FOR AMMO MAG POWER SYSTEM MODIFICATIONS |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | CONTROLLER, MAGNETIC,SIZE 1, LVR,450VAC 3PH 60HZ |