NSN 6110-01-528-5608
Part Details | MOTOR CONTROLLER
6110-01-528-5608 A device which, in addition to starting and stopping a motor, performs one or more of the following functions: reverses the rotation, selects the speed, and/or regulates the speed of a motor. Includes items of this type whose design provides means for operation with a rheostat or speed regulator which may be integral or included. Items such as drum switches may be included. See also STARTER, MOTOR.
Alternate Parts: 215063010, 215-063-010, PL215063010, PL215-063-010, 6110-01-528-5608, 01-528-5608, 6110015285608, 015285608
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | MAR 17, 2005 | 01-528-5608 | 00904 ( CONTROLLER, MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-528-5608
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 215-063-010 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER,INC. |
| PL215-063-010 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER,INC. |
Technical Data | NSN 6110-01-528-5608
| Characteristic | Specifications |
|---|---|
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| SIZE DESIGNATOR | 2 |
| OPERATING VOLTAGE CHARACTERISTIC | FULL |
| AC VOLTAGE RATING | 440.0 VOLTS NOMINAL |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| PHASE | THREE |
| HORSEPOWER RATING | 25.000 |
| FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
| FUSE ACCOMMODATION QUANTITY | 2 |
| FUSE CURRENT RATING IN AMPS | 10.0 |
| ACTUATION METHOD | MAGNETIC |
| LOAD PROTECTION TYPE | OVERLOAD |
| DUTY CYCLE | CONTINUOUS |
| AMBIENT TEMP | 50.0 DEG CELSIUS |
| INCLOSURE FEATURE | DRIPPROOF |
| OVERALL WIDTH | 9.760 INCHES NOMINAL |
| OVERALL LENGTH | 20.120 INCHES NOMINAL |
| OVERALL HEIGHT | 16.120 INCHES NOMINAL |
| MOUNTING CONFIGURATION | WALL MOUNT; 4 BOLTS 0.500 INCHES DIA, GRADE 5 (MIN), TORQUE TO 90 LB - FT |
| SPECIAL FEATURES | CPS REFERENCE: TYPE 7AA2 |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | MOTOR CONTROLLER SS-63 FAN MOTOR ASSEMBLY |