NSN 6130-01-629-8321
Part Details | POWER SUPPLY
6130-01-629-8321 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.
Alternate Parts: VHDC24V50W, VHDC-24V-50W, 6130-01-629-8321, 01-629-8321, 6130016298321, 016298321
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JUL 16, 2014 | 01-629-8321 | 00740 ( POWER SUPPLY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6130-01-629-8321
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| VHDC-24V-50W | 3CSS4 | RAJANT CORPORATION |
Technical Data | NSN 6130-01-629-8321
| Characteristic | Specifications |
|---|---|
| VENTILATION DESIGN TYPE | AIR COOLED |
| ENVIRONMENTAL PROTECTION | DUSTPROOF AND WEATHERPROOF |
| OVERALL LENGTH | 6.125 INCHES NOMINAL |
| OVERALL WIDTH | 3.25 INCHES NOMINAL |
| OVERALL HEIGHT | 1.65 INCHES NOMINAL |
| INSTALLATION DESIGN | HOLE |
| OPERATING AMBIENT TEMP RANGE | -40.0 TO +100.0 DEG CELSIUS |
| SPECIAL FEATURES | SWITCHING FREQUENCY 300 KHZ |
| END ITEM IDENTIFICATION | ROCKET ANTI-MORTAR WARNING SYSTEM |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | DC/DC CONVERTER |