NSN 6625-01-020-6302

Part Details | OSCILLOSCOPE

6625-01-020-6302 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.

Alternate Parts: 4750PT47, 4750PT4-7, 47547, 475-4-7, 6625-01-020-6302, 01-020-6302, 6625010206302, 010206302

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66MAY 01, 197601-020-630200357 ( OSCILLOSCOPE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-020-6302
Part Number Cage Code Manufacturer
4750PT4-703950NAVAL INVENTORY CONTROL POINTMECHANICSBURG
475-4-780009TEKTRONIX, INC.DBA TEKTRONIX
Technical Data | NSN 6625-01-020-6302
Characteristic Specifications
SCREEN SIZE8 BY 10 CENTIMETERS
BEAM QUANTITY1
SWEEP CIRCUITS INCLUDED
GENERATOR DRIVEN FEATURE NOT INCLUDED
SWEEP CIRCUIT TYPED ANY ACCEPTABLE AND F ANY ACCEPTABLE
AMPLIFIER DEFLECTION SENSITIVITY PROVISION NOT PROVIDED
INPUT INTENSITY MODULATION FEATURE NOT PROVIDED
PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION NOT PROVIDED
FREQUENCY RESPONSE RATING NOT PROVIDED
AMPLIFIER INPUT IMPEDANCE RATING PROVISION NOT PROVIDED
AMPLITUDE CALIBRATING VOLTAGE WAVEFORM ANY ACCEPTABLE
CALIBRATING PEAK TO PEAK AMPLITUDE0.3 VOLTS NOMINAL
CALIBRATED SCREEN SCALE INCLUDED
GRADUATION INTERVALGRADUATED IN 0.2 CM INCREMENTS
TRACE STORAGE TUBE NOT INCLUDED
CAMERA RECORDING DEVICE ACCOMMODATION NOT PROVIDED
CURRENT TYPE AC AND DC
VOLTAGE RATING12.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM
FREQUENCY RATING48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM
PHASE SINGLE
MOUNTING METHOD TABLE
ACCESSORY COMPONENTS AND QUANTITY6 FT PROBES 2,BLUE CRT LIGHT FILTER 1,CLEAR CRT LIGHT FILTER 1,GROUN D POST 1