NSN 6625-01-129-2904
Part Details | FAULT LOCATING INDICATOR
6625-01-129-2904 An electrically activated item specifically designed to indicate the occurrence of a malfunction in a component of an electronic set, central or system. It may indicate the malfunction by a pop-out button (e.g. ground fault interrupt outlets) or color change by emitted light or displayed in a window. The indicator may utilize a "push to test" button. It does not make quantitative or qualitative tests such a provided by test sets.
Alternate Parts: BHGD21T6BLKW, BHGD21T6BLKW, 2832212140, A1231444, 6625-01-129-2904, 01-129-2904, 6625011292904, 011292904
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | APR 04, 1982 | 01-129-2904 | 60639 ( INDICATOR, FAULT LOCATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-129-2904
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| BHGD21T6BLKW | 10236 | ELECTRODYNAMICS, INC.DBA L-3 COMMUNICATIONS |
| BHGD21T6BLKW | 07479 | MINELCO INCSUB OF TALLEY INDUSTRIES INC |
| 2832212140 | F9111 | THALES AVIONICS SAS |
| A1231444 | F9111 | THALES AVIONICS SAS |
Technical Data | NSN 6625-01-129-2904
| Characteristic | Specifications |
|---|---|
| CASE MATERIAL | ALUMINUM |
| PRESENTATION TYPE | DROP FLAGS |
| CURRENT TYPE | DC |
| DC VOLTAGE RATING | 6.0 VOLTS NOMINAL |
| COIL DC RESISTANCE | 1000000.0 OHMS NOMINAL |
| CONTACT QUANTITY | 4 |
| CONTACT TYPE | SOLDER LUG |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED CASE |
| LENGTH | 1.260 INCHES MINIMUM AND 1.320 INCHES MAXIMUM |
| DIAMETER | 0.320 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
| FEATURES PROVIDED | COIL AND HERMETICALLY SEALED CASE AND WATERPROOF |
| SPECIAL FEATURES | 32 THDS PER IN. UNEF 2A; OPERATING PULSE LENGTH 20.0 MSEC OR GREATER; SEALED GLASS WINDOW; MAGNETIC LATCHING; THREADED BODY MOUNTING PROVISION |