NSN 6625-01-136-2419

Part Details | WATTMETER

6625-01-136-2419 An instrument which measures one or more different electrical power quantities (such as decibels and watts), and is calibrated using watts. The power measurement and/or calibration may be displayed in multiples and/or submultiples thereof on a dial and/or digital readout display. For items designed to measure radio frequency power see TEST SET, ELECTRICAL POWER and METER, MULTIPLE SCALE. Excludes: AMMETER; FREQUENCY METER; MULTIMETER; VOLTMETER.

Alternate Parts: 078218JQQXH, 078-218J-QQXH, 078218AQQXH, 078-218-A-QQXH, 6625-01-136-2419, 01-136-2419, 6625011362419, 011362419

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66AUG 05, 198201-136-241928455 ( WATTMETER )
REFERENCE DRAWINGS & PICTURES

FOUR HOLE/STUD RECTANGULAR/SQUARE

RECTANGULAR FLUSH MTG

Cross Reference | NSN 6625-01-136-2419
Part Number Cage Code Manufacturer
078-218J-QQXH53498TYCO ELECTRONICS CROMPTON INSTRUMENT
078-218-A-QQXH53498TYCO ELECTRONICS CROMPTON INSTRUMENT
Technical Data | NSN 6625-01-136-2419
Characteristic Specifications
INSTALLATION DESIGN PANEL
INDICATOR TYPE DIAL W/POINTER
MOVEMENT TYPE MOVING COIL, PERMANENT MAGNET
MOVEMENT SUSPENSION METHOD TAUT BAND
FREQUENCY RESPONSE RANGE+50.000 TO +60.000 HERTZ
CIRCUIT ATTACHMENT METHOD AND QUANTITY8 THREADED STUD
SENSITIVITY RATING120.0 VOLT-AMPERES
SCALE SELECTION METHOD TERMINAL
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS3000.0
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED AC
OPERATING VOLTAGE RATING IN VOLTS120.0 AC NOMINAL
FREQUENCY RATING60.0 HERTZ NOMINAL
PHASE THREE
STYLE DESIGNATOR RECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE3.970 INCHES MAXIMUM
METER DEPTH BEHIND MOUNTING FLANGE5.190 INCHES MAXIMUM
OVERALL HEIGHT4.300 INCHES MAXIMUM
OVERALL LENGTH7.040 INCHES MAXIMUM
OVERALL WIDTH4.300 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 SCREW AND 4 UNTHREADED HOLE
MOUNTING HOLE DIAMETER0.310 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLE FOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.380 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.380 INCHES NOMINAL
MATERIAL STEEL
SURFACE TREATMENT CHROMATE
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
ENVIRONMENTAL PROTECTION AIRTIGHT AND DUST RESISTANT AND FUNGUS RESISTANT AND HEAT RESISTANT AND HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND WATER RESISTANT
FURNISHED ITEMS AND QUANTITYNUT 12; LOCKWASHER 12; SEAL 1
SPECIAL MARKINGSON BACK,SEALED DO NOT OPEN
FEATURES PROVIDED MAGNETIC SHIELD AND ZERO ADJUSTER
SPECIAL FEATURESRUGGEDIZED; SEALED
SPECIAL TEST FEATURESCOMPLIES WITH MIL-M-10304
FSC APPLICATION DATATEST SET,ELECT. EQUIP.