NSN 6625-01-195-7514

Part Details | VOLTMETER

6625-01-195-7514 An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

Alternate Parts: 405769 ITEM 75, 4057-69 ITEM 75, 92150689, 9-2150-689, 21500HL100DCMV, 2150A5005AE0689, 92150689, 9-2150-689, 2150A5005AE0689, 6625-01-195-7514, 01-195-7514, 6625011957514, 011957514

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66DEC 01, 198401-195-751416449 ( VOLTMETER )
REFERENCE DRAWINGS & PICTURES

FOUR HOLE/STUD RECTANGULAR/SQUARE

RECTANGULAR FLUSH MTG

Cross Reference | NSN 6625-01-195-7514
Part Number Cage Code Manufacturer
4057-69 ITEM 7543689HUNTINGTON INGALLS INCORPORATEDDIV NEWPORT NEWS
9-2150-68981030PRIME TECHNOLOGY INCINTERNATIONAL INSTRUMENTS DIV
21500HL100DCMV81030PRIME TECHNOLOGY INCINTERNATIONAL INSTRUMENTS DIV
2150A5005AE068981030PRIME TECHNOLOGY INCINTERNATIONAL INSTRUMENTS DIV
9-2150-6890BHF9PRIME TECHNOLOGY, LLC
2150A5005AE06890BHF9PRIME TECHNOLOGY, LLC
Technical Data | NSN 6625-01-195-7514
Characteristic Specifications
INSTALLATION DESIGN PANEL
INDICATOR TYPE DIAL W/POINTER
MOVEMENT TYPE MOVING COIL, PERMANENT MAGNET
MOVEMENT SUSPENSION METHOD JEWEL PIVOT BASE
CIRCUIT ATTACHMENT METHOD AND QUANTITY4 THREADED STUD
SCALE SELECTION METHOD TERMINAL
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED DC
STYLE DESIGNATOR RECTANGULAR FLUSH MTG
METER BODY HEIGHT BEHIND MOUNTING FLANGE1.230 INCHES NOMINAL
METER BODY WIDTH BEHIND MOUNTING FLANGE5.435 INCHES NOMINAL
METER DEPTH BEHIND MOUNTING FLANGE5.760 INCHES NOMINAL
OVERALL HEIGHT1.520 INCHES NOMINAL
OVERALL LENGTH6.030 INCHES NOMINAL
OVERALL WIDTH6.690 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD
MOUNTING STUD DIAMETER0.190 INCHES NOMINAL
MOUNTING STUD LENGTH0.500 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLE FOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH6.050 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.725 INCHES NOMINAL
MATERIAL PLASTIC AND STEEL
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED