NSN 6625-01-214-2479
Part Details | WATTMETER
6625-01-214-2479 An instrument which measures one or more different electrical power quantities (such as decibels and watts), and is calibrated using watts. The power measurement and/or calibration may be displayed in multiples and/or submultiples thereof on a dial and/or digital readout display. For items designed to measure radio frequency power see TEST SET, ELECTRICAL POWER and METER, MULTIPLE SCALE. Excludes: AMMETER; FREQUENCY METER; MULTIMETER; VOLTMETER.
Alternate Parts: 409C685A59 0400KW, 409C685A59 0-400KW, 6625-01-214-2479, 01-214-2479, 6625012142479, 012142479
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | AUG 08, 1985 | 01-214-2479 | 28455 ( WATTMETER ) |
REFERENCE DRAWINGS & PICTURES
FOUR HOLE/STUD RECTANGULAR/SQUARE
RECTANGULAR FLUSH MTG
Cross Reference | NSN 6625-01-214-2479
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 409C685A59 0-400KW | 88416 | HUGHES CORPORATIONDBA WESCHLER INSTRUMENTS |
Technical Data | NSN 6625-01-214-2479
| Characteristic | Specifications |
|---|---|
| INSTALLATION DESIGN | PANEL |
| INDICATOR TYPE | DIAL W/POINTER |
| MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
| MOVEMENT SUSPENSION METHOD | TAUT BAND |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
| SCALE SELECTION METHOD | TERMINAL |
| POWER SOURCE | EXTERNAL |
| CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
| STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 3.960 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 3.750 INCHES NOMINAL |
| OVERALL HEIGHT | 4.422 INCHES NOMINAL |
| OVERALL LENGTH | 4.437 INCHES NOMINAL |
| OVERALL WIDTH | 4.422 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
| MOUNTING STUD DIAMETER | 0.250 INCHES NOMINAL |
| MOUNTING STUD LENGTH | 0.625 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.376 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.376 INCHES NOMINAL |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| FSC APPLICATION DATA | TEST SET ELECTRONIC |