6625-01-214-3258 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.

Alternate Parts: OS284G, OS-284/G, SC504A, SC-504A, 6625-01-214-3258, 01-214-3258, 6625012143258, 012143258

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66AUG 08, 198501-214-325800357 ( OSCILLOSCOPE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-214-3258
Part Number Cage Code Manufacturer
OS-284/G80058JOINT ELECTRONICS TYPE DESIGNATIONSYSTEM
SC-504A80009TEKTRONIX, INC.DBA TEKTRONIX
Technical Data | NSN 6625-01-214-3258
Characteristic Specifications
SCREEN SIZE2.0 X 2.5 INCHES
BEAM QUANTITY2
SWEEP CIRCUITS INCLUDED
SWEEP CIRCUIT TYPE ANY ACCEPTABLE
SWEEP FREQUENCY RANGE+0.0 TO +80.0 MEGAHERTZ
SINGLE TRIGGER SWEEP DURATIONEFB50.0 NANOSECONDS AND ARC0.2 SECONDS
TRIGGER SWEEP VOLTAGE AMPLITUDE RATING250.0 VOLTS MAXIMUM
TRIGGER SWEEP POLARITY SWITCH NOT INCLUDED
TRIGGER SWEEP MARKER INTERVALS20 MSEC AND 50 NSEC
EXPANDED SWEEP NOT PROVIDED
AMPLIFIER DEFLECTION SENSITIVITY PROVISION PROVIDED
INPUT INTENSITY MODULATION FEATURE PROVIDED
CALIBRATING PEAK TO PEAK AMPLITUDE5.0 MILLIVOLTS MINIMUM AND 10.0 VOLTS MAXIMUM
ACCURACY RANGE IN PERCENTM3.0/P3.0
MEASUREMENT RANGE QUANTITY8
MEASUREMENT RANGE STEPSCONTINUOUSLY VARIABLE; AT LEAST 2.5:1 RANGE; 25 V/DIV MAXIMUM
CALIBRATED SCREEN SCALE NOT INCLUDED
TRACE STORAGE TUBE NOT INCLUDED
VIEWING SCREEN VOLTAGE RATING250.0 VOLTS
TRACE ERASING PROVISION NOT PROVIDED
CAMERA RECORDING DEVICE ACCOMMODATION NOT PROVIDED
CURRENT TYPE AC AND DC
VOLTAGE RATING400.0 VOLTS NOMINAL AND 250.0 VOLTS NOMINAL
MOUNTING METHOD CABINET W/COMPLETE HARDWARE FOR RACK
SPECIAL FEATURESHIGH WRITING SPEED AND VERSATILE TRIGGERING
TEST DATA DOCUMENT80009-S-504A DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
END ITEM IDENTIFICATIONSIGNAL COLLECTION SYSTEM AN/GSQ- 212
SUPPLEMENTARY FEATURESOPERATING POWER 26 WATTS; RISE TIME 4.4 NANOSECONDS OR LESS; BAND WIDTH MEASURED AT -3 DB POINTS; MOUNT IN STANDARD 19-INCH RACK; DESIGNED FORGROUND USE