NSN 6625-01-221-0086
Part Details | ELECTRICAL CABLE TEST SET
6625-01-221-0086 A test set primarily designed for use in making examinations of electrical cables. Can be used for locating shorts, crosses, and grounds in electrical cables. This would also permit locating high resistant faults. See also TEST SET (1), POWER-SPECIAL PURPOSE ELECTRICAL CABLE ASSEMBLY. Excludes REFLECTOMETER, METALLIC TIME DOMAIN.
Alternate Parts: 573AP, 573A/P, 573AP, 573A/P, 573, 573AP, 573A/P, 6625-01-221-0086, 01-221-0086, 6625012210086, 012210086
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | NOV 22, 1985 | 01-221-0086 | 03633 ( TEST SET, ELECTRICAL CABLE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-221-0086
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 573A/P | 55203 | 3M COMPANYDIV ELECTRO AND COMMUNICATIONS |
| 573A/P | 53387 | 3M COMPANYDIV ELECTRO AND COMMUNICATIONS |
| 573 | 53186 | DYNATEL CORP |
| 573A/P | 75037 | MINNESOTA MINING AND MFG CO 3MCOMPANY |
Technical Data | NSN 6625-01-221-0086
| Characteristic | Specifications |
|---|---|
| TEST TYPE FOR WHICH DESIGNED | CABLE TRACING AND FAULT LOCATING |
| INCLOSURE FEATURE | MULTIPLE ITEM W/CARRYING CASE |
| SPECIAL FEATURES | DESIGNED FOR TELEPHONE CABLE AND SHEATH FAULT LOCATION;HAS A 300KHZ CABLE TRACER TONE;BATTERY OPERATED;INCLUDDES FAULT DIRECTION AND LEVEL REFERENCE METER, 2 DYNA-COUPLERS AND 12 FOOT EXTENSION CABLE |
| FUNCTIONAL DESCRIPTION | IDENTIFIES, TRACES AND LOCATES FAULTS IN POWER AND TRANSMISSION CABLES SUCH AS SHORTS, OPENS, AND GROUNDS |