NSN 6625-01-225-7011
Part Details | VOLTMETER
6625-01-225-7011 An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.
Alternate Parts: G3006051, G300605-1, 60819658, 608-19658, 6625-01-225-7011, 01-225-7011, 6625012257011, 012257011
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | FEB 06, 1986 | 01-225-7011 | 16449 ( VOLTMETER ) |
REFERENCE DRAWINGS & PICTURES
ROUND FLUSH MTG
Cross Reference | NSN 6625-01-225-7011
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| G300605-1 | 24930 | HARRIS CORPORATIONDBA ELECTRONIC SYSTEMS, RADAR |
| 608-19658 | 77221 | PHAOSTRON INSTRUMENT AND ELECTRONICCOMPANY |
Technical Data | NSN 6625-01-225-7011
| Characteristic | Specifications |
|---|---|
| INSTALLATION DESIGN | PANEL |
| INDICATOR TYPE | DIAL W/POINTER |
| MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
| MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 SOLDER LUG |
| SENSITIVITY RATING | 1.0 MILLIAMPERES |
| DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1000.0 |
| POWER SOURCE | EXTERNAL |
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
| STYLE DESIGNATOR | ROUND FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 1.000 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 0.375 INCHES MINIMUM |
| OVERALL DIAMETER | 1.250 INCHES NOMINAL |
| OVERALL LENGTH | 1.251 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BODY |
| MATERIAL | 0$DSTA000 |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT |
| FURNISHED ITEMS AND QUANTITY | NUT 2 |
| FEATURES PROVIDED | MAGNETIC SHIELD AND ZERO ADJUSTER |
| SPECIAL FEATURES | RUGGEDIZED |
| SPECIAL TEST FEATURES | CONFORMS TO MIL-M-10304/30,TYPE MR06W001DCMAR |
| SPECIFICATION/STANDARD DATA | 24930-G300605-1 MANUFACTURERS SPECIFICATION CONTROL |
| FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |