NSN 6625-01-233-2274

Part Details | WATTMETER

6625-01-233-2274 An instrument which measures one or more different electrical power quantities (such as decibels and watts), and is calibrated using watts. The power measurement and/or calibration may be displayed in multiples and/or submultiples thereof on a dial and/or digital readout display. For items designed to measure radio frequency power see TEST SET, ELECTRICAL POWER and METER, MULTIPLE SCALE. Excludes: AMMETER; FREQUENCY METER; MULTIMETER; VOLTMETER.

Alternate Parts: MR492W600ACKWH, MR492W600ACKWH, MILW19088, MIL-W-19088, 6625-01-233-2274, 01-233-2274, 6625012332274, 012332274

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66MAY 28, 198601-233-227428455 ( WATTMETER )
REFERENCE DRAWINGS & PICTURES

FOUR HOLE/STUD RECTANGULAR/SQUARE

RECTANGULAR FLUSH MTG

Cross Reference | NSN 6625-01-233-2274
Part Number Cage Code Manufacturer
MR492W600ACKWH15309JEWELL INSTRUMENTS, LLCDBA MODUTEC USE CAGE CODE 33005 FOR
MR492W600ACKWH81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-W-1908881349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
Technical Data | NSN 6625-01-233-2274
Characteristic Specifications
INSTALLATION DESIGN PANEL
INDICATOR TYPE DIAL W/POINTER
CIRCUIT ATTACHMENT METHOD AND QUANTITY2 THREADED STUD
SCALE SELECTION METHOD TERMINAL
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS2600.0
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED AC
FREQUENCY RATING60.0 HERTZ NOMINAL
PHASE THREE
STYLE DESIGNATOR RECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE3.980 INCHES MAXIMUM
METER DEPTH BEHIND MOUNTING FLANGE9.000 INCHES MAXIMUM
OVERALL HEIGHT4.250 INCHES MINIMUM AND 4.750 INCHES MAXIMUM
OVERALL LENGTH11.000 INCHES MAXIMUM
OVERALL WIDTH4.250 INCHES MINIMUM AND 4.750 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 SCREW AND 4 UNTHREADED HOLE
MOUNTING HOLE DIAMETER0.312 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLE FOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.376 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.376 INCHES NOMINAL
MATERIAL PLASTIC
MATERIAL DOCUMENT AND CLASSIFICATIONMIL-P-14 MIL SPEC SINGLE MATERIAL RESPONSE
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
ENVIRONMENTAL PROTECTION HUMIDITY RESISTANT AND SPLASH PROOF AND VIBRATION RESISTANT
FURNISHED ITEMS AND QUANTITYMTG HDW 4; TERM. HDW 2
FEATURES PROVIDED MAGNETIC SHIELD AND ZERO ADJUSTER
SPECIAL FEATURESHIGH IMPACT RESISTANT
TEST DATA DOCUMENT81349-MIL-W-19088 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL-W-19088 GOVERNMENT SPECIFICATION
FSC APPLICATION DATATEST SET,ELECT. EQUIP.