NSN 6625-01-249-7104

Part Details | LINE VOLTAGE INDICATOR

6625-01-249-7104 An item specifically designed to test and/or monitor an electrical circuit and indicate its operating condition by means of a display, such as lamps or light emitting diodes. Examples of conditions being indicated are power on, no power, reversed polarity, open ground, open neutral, alternating current and/or direct current. It may or may not be used to indicate definite power line voltage ratings, such as 110, 220 and 440 volts. It is designed to be inserted in the circuit being tested. For items designed to indicate with out physical contact with the object being tested, see INDICATOR, ELECTRICAL POTENTIAL. See also LIGHT, TEST, and VOLTMETER.

Alternate Parts: 4001416, M50A, 6625-01-249-7104, 01-249-7104, 6625012497104, 012497104

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66FEB 14, 198701-249-710416409 ( INDICATOR, LINE VOLTAGE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-249-7104
Part Number Cage Code Manufacturer
400141612038ILLINOIS TOOL WORKS INCDBA SIMCO
M50A12038ILLINOIS TOOL WORKS INCDBA SIMCO
Technical Data | NSN 6625-01-249-7104
Characteristic Specifications
VOLTAGE IN VOLTS AND CURRENT TYPE120.0 AC
CURRENT RATING12.500 MILLIAMPERES
SPECIAL FEATURESVOLTAGE REQUIREMENTS 120 VAC, 50/60 HZ; INPUT RESISTANCE TO GROUND 3 MEGOHMS NOMINAL; RESISTANCE EXCEEDING 3 MEGOHMS TRIGGERS ALARM; OPERATING TEMP RANGE 32 DEG F TO 122 DEG F; WEIGHT 1 LB; ENCLOSURES: ALUMINUM, BEIGE AND BROWN ENAMEL INPUT JACK ON FRONT PANEL OF MONITOR; GREEN LED GLOWS TO SHOW THE WRIST STRAP IS IN PROPER WORKING ORDER; IF LED GOES OUT AND A RED LED AND AUDIBLE ALARM SOUND IT WILL ALERT THE OPERATOR TO CHECK THE STRAP; FURNISHED WITH MOUNTING BRACKET FOR MOUNTING ON OR BELOW THE WORK SURFACE; DIMENSIONS OF MONITOR 4 9/16 WIDE AND 1 15/16 INCH HIGH
FUNCTIONAL DESCRIPTIONCONSTANT MONITORING OF WRIST STRAPS, DETECTS INTERMITTENT PROBLEMS, ACCEPTS ANY CONDUCTIVE WRIST STRAP WITH BANANA HZ PLUG; BUILT IN AUDIBLE AND VISUAL ALARMS; FOR USE AT STATIC PROTECTIVE WORK STATIONS; PERFORMS CONTINUITY CHECKS ON THE WRIST STRAP TO DETECT ANY OPEN CIRCUIT WHICH MAY OCCUR BETWEEN THE USER AND GROUND
PART NAME ASSIGNED BY CONTROLLING AGENCYWRIST STRAP MONITOR