NSN 6625-01-275-4759
Part Details | METALLIC TIME DOMAIN REFLECTOMETER
6625-01-275-4759 A cable tester that uses time domain reflectometry to identify and locate cable faults.
Alternate Parts: 1502BOPT0304, 1502BOPT03/04, 6625-01-275-4759, 01-275-4759, 6625012754759, 012754759
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | MAR 22, 1988 | 01-275-4759 | 66586 ( REFLECTOMETER, METALLIC TIME DOMAIN ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-275-4759
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 1502BOPT03/04 | 80009 | TEKTRONIX, INC.DBA TEKTRONIX |
Technical Data | NSN 6625-01-275-4759
| Characteristic | Specifications |
|---|---|
| POWER SOURCE | EXTERNAL AND SELF-CONTAINED |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
| FREQUENCY IN HERTZ | 45.0 |
| MAXIMUM MEASURED DISTANCE | 2000.0 FEET |
| OVERALL LENGTH | 16.500 INCHES NOMINAL |
| OVERALL HEIGHT | 5.000 INCHES NOMINAL |
| OVERALL WIDTH | 12.400 INCHES NOMINAL |
| SPECIAL FEATURES | SINGLE PHASE; INCLOSURE FEATURE, SINGLE ITEM W/HOUSING; SURFACE TREATMENT, ANY ACCEPTABLE; ACCESSORIES INLUDED: AC POWER CORD; 50 OHM BNC TERMINATOR (011-0123-00); PRECISION 50 OHM CABLE (012-0482-00); FEMALE-TO-FEMALE BNC CONNECTOR (103-0028-00); SPARE FUSE; OPERATOR'S MANUAL (070-6266-00); OPT 04 ADDS RECORDER; OPT 03 IS BATTERY PACK; MAXIMUM AC VOLTS 230; MAX HZ 440 |
| FUNCTIONAL DESCRIPTION | METALLIC CABLE TESTING |