NSN 6625-01-298-0156
Part Details | INSULATION BREAKDOWN TEST SET
6625-01-298-0156 A test set primarily designed to detect and indicate insulation breakdown in electric motors, transformers, and the like, at specific test voltages. See also TEST SET, ARMATURE; and OHMMETER.
Alternate Parts: 231215, 215L2, 215-L/2, 6625-01-298-0156, 01-298-0156, 6625012980156, 012980156
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | APR 08, 1989 | 01-298-0156 | 16408 ( TEST SET, INSULATION BREAKDOWN ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-298-0156
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 231215 | 07239 | AVO INTL |
| 215-L/2 | 07239 | AVO INTL |
Technical Data | NSN 6625-01-298-0156
| Characteristic | Specifications |
|---|---|
| OUTPUT CURRENT TYPE | AC AND DC |
| OUTPUT VOLTAGE RATING | 0.000 KILOVOLTS MINIMUM AND 6.000 KILOVOLTS MAXIMUM |
| OUTPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| OUTPUT CURRENT RATING | 8.900 MILLIAMPERES NOMINAL |
| INSTALLATION DESIGN | PANEL |
| LEAKAGE INDICATOR TYPE | METER |
| METER QUANTITY | A1$$A1 |
| METER TYPE | AMMETER AND VOLTMETER |
| SCALE RANGE | +0.0 TO +12.0 KILOVOLTS |
| AC VOLTAGE RATING | 120.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |
| FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| PHASE | SINGLE |
| OVERALL LENGTH | 19.500 INCHES NOMINAL |
| OVERALL WIDTH | 11.750 INCHES NOMINAL |
| OVERALL HEIGHT | 7.500 INCHES NOMINAL |