NSN 6625-01-298-2193
Part Details | INSULATION BREAKDOWN TEST SET
6625-01-298-2193 A test set primarily designed to detect and indicate insulation breakdown in electric motors, transformers, and the like, at specific test voltages. See also TEST SET, ARMATURE; and OHMMETER.
Alternate Parts: 4450DT, 6625-01-298-2193, 01-298-2193, 6625012982193, 012982193
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | APR 13, 1989 | 01-298-2193 | 16408 ( TEST SET, INSULATION BREAKDOWN ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-298-2193
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 4450DT | 04237 | ASSOCIATED RESEARCH INCORPORATED |
Technical Data | NSN 6625-01-298-2193
| Characteristic | Specifications |
|---|---|
| OUTPUT CURRENT TYPE | AC AND DC |
| OUTPUT VOLTAGE RATING | 0.000 KILOVOLTS MINIMUM AND 5.000 KILOVOLTS MAXIMUM |
| OUTPUT FREQUENCY RATING | 50.0 HERTZ NOMINAL AND 60.0 HERTZ NOMINAL |
| OUTPUT CURRENT RATING | 15.000 MILLIAMPERES MAXIMUM |
| INSTALLATION DESIGN | PORTABLE |
| LEAKAGE INDICATOR TYPE | METER |
| METER QUANTITY | 2 |
| METER TYPE | AMMETER AND VOLTMETER |
| SCALE RANGE | +0.7 TO +15.0 MILLIAMPS AND +0.0 TO +5.0 KILOVOLTS |
| AC VOLTAGE RATING | 120.0 VOLTS NOMINAL |
| FREQUENCY RATING | 50.0 HERTZ NOMINAL AND 60.0 HERTZ NOMINAL |
| PHASE | SINGLE |
| OVERALL LENGTH | 12.000 INCHES NOMINAL |
| OVERALL WIDTH | 12.000 INCHES NOMINAL |
| OVERALL HEIGHT | 7.000 INCHES NOMINAL |
| SPECIAL FEATURES | FAULT DETECTION VISUAL AND AUDIO ALARMS; TESTS CAN BE DONE BY REMOTE CONTROL; EQUIPPED WITH 7 1/2 FT. DETACHABLE 3-CONDUCTOR CORD W/3-PRONG GROUNDING TYPE PLUG |