Part Details | ELECTRONIC CIRCUIT PLUG-IN UNIT TEST SET
6625-01-300-8142 A test set specifically designed for use in making examination of plug-in items, commonly referred to as modules or potted components, that are part of an electronic equipment. These plug-in items are inclosed and sealed in a case, and are provided with plug-type connectors for insertion into or removal from the component or equipment of which they are a part. It includes items that test circuit cards, that may or may not be encased and/or sealed, used with electronic computers. Excludes TEST SET (1), ELECTRON TUBE and TEST SET, VIBRATOR.
Alternate Parts: 6228781001, 622-8781-001, 6625-01-300-8142, 01-300-8142, 6625013008142, 013008142
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | MAY 18, 1989 | 01-300-8142 | 61200 ( TEST SET, ELECTRONIC CIRCUIT PLUG-IN UNIT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-300-8142
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 622-8781-001 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
Technical Data | NSN 6625-01-300-8142
| Characteristic | Specifications |
|---|---|
| TEST TYPE FOR WHICH DESIGNED | CIRCUIT CARD TOTAL PERFORMANCE |
| INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
| HEIGHT | 15.320 INCHES NOMINAL |
| LENGTH | 17.340 INCHES NOMINAL |
| WIDTH | 17.250 INCHES NOMINAL |
| SUPPLEMENTARY FEATURES | WEIGHT 27 LBS; INPUT POWER REQUIRMENTS 115 OR 230 V AC,50 TO 60 HZ; COOLING: NONE; INPUT SIGNALS; LOGIC 0 OR GROUND - NOT MORE THAN P0.7 VDC,LOGIC 1 NOT LESS THAN P3.7 VDC,NOT LESS THAN P10 VDC FOR CMOS CIRCUITS; USED ON CIRCUIT CARDS FROM THE HF-8022 10KW POWER AMPLIFER AND THE HF-8030 1 KW POWER SUPPLY |