NSN 6625-01-319-3859
Part Details | WATTMETER
6625-01-319-3859 An instrument which measures one or more different electrical power quantities (such as decibels and watts), and is calibrated using watts. The power measurement and/or calibration may be displayed in multiples and/or submultiples thereof on a dial and/or digital readout display. For items designed to measure radio frequency power see TEST SET, ELECTRICAL POWER and METER, MULTIPLE SCALE. Excludes: AMMETER; FREQUENCY METER; MULTIMETER; VOLTMETER.
Alternate Parts: 118.100, 1800, 10071602, 100716-02, 6625-01-319-3859, 01-319-3859, 6625013193859, 013193859
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | MAY 05, 1990 | 01-319-3859 | 28455 ( WATTMETER ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR OR SQUARE
Cross Reference | NSN 6625-01-319-3859
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 118.100 | 1ES16 | CHAUVIN ARNOUX INC |
| 1800 | 1ES16 | CHAUVIN ARNOUX INC |
| 100716-02 | 03691 | E I L INSTRUMENTS INC |
Technical Data | NSN 6625-01-319-3859
| Characteristic | Specifications |
|---|---|
| INSTALLATION DESIGN | HAND HELD |
| INDICATOR TYPE | DIGITAL DISPLAY |
| DISPLAY TYPE | LIQUID CRYSTAL |
| DISPLAY DIGIT QUANTITY | 3-1/2 |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 4 CLAMP-ON |
| DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 2000.0 |
| POWER SOURCE | INTERNAL |
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
| OPERATING VOLTAGE RATING IN VOLTS | 6.7 DC MINIMUM AND 10.0 DC MAXIMUM |
| PHASE | SINGLE |
| STYLE DESIGNATOR | 1 RECTANGULAR OR SQUARE |
| OVERALL DEPTH | 3.150 INCHES NOMINAL |
| OVERALL HEIGHT | 1.700 INCHES NOMINAL |
| OVERALL LENGTH | 7.400 INCHES NOMINAL |
| OVERALL WIDTH | 3.800 INCHES NOMINAL |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| SPECIAL FEATURES | INPUT CURRENT TO 1000 AAC; INPUT VOLTAGE TO 600VAC; CLAMP-ON CURRENT TRANSFORMERS AVAILABLE AS OPTS IN 4 RANGGES AND SIZES TO CONNECT ON WIRE,CABLE,BUS BAR,OR MULTI-CONDUCTOR CABLE; MAY ALSO BE USED TO CONNECT CT'S WITH 5 AMP SECONDARY; 9 VOLT ALKALINE BATTERY W/ LOW BATTERY INDICATOR,CURRENT OVERLOAD INDICATOR; METER SUPPLIED WITH1000/1 STANDARD CLAMP-ON CURRENT TRANSFORMER,VOLTAGE LEADS,SET OF 2 CURRENT LEADS,AND MANUAL |
| SUPPLEMENTARY FEATURES | TESTING OF OXYGEN CONCENTRATOR ASSSY P/N 2348W000 |
| FUNCTIONAL DESCRIPTION | MEASURES ACTIVE AND REACTIVE POWER ON POLYPHASE CIRCUITS AND POWER CONSUMPTION ON SINGLE AND THREE PHASE SYS |
| END ITEM IDENTIFICATION | MOLECULAR SIEVE OXYGEN GENERATIONSYSTEM (MSOGS),B1-B AIRCRAFT |