NSN 6625-01-329-4423
Part Details | SPECIAL SCALE METER
6625-01-329-4423 An electrically operated instrument which has a custom scale or digital readout display, but the unit of measurement given is not covered by a more specific item name. For items without a specified unit of measurement, see METER, ARBITRARY SCALE.
Alternate Parts: 214A24VDC, 214A-24VDC, 21424VDC, 214-24VDC, 214A24VDC, 214A-24VDC, 214L24VDC, 214L-24VDC, 214A24VDC, 214A-24VDC, 20424VDC, 204-24VDC, 6625-01-329-4423, 01-329-4423, 6625013294423, 013294423
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | NOV 16, 1990 | 01-329-4423 | 61955 ( METER, SPECIAL SCALE ) |
REFERENCE DRAWINGS & PICTURES
FOUR HOLE/STUD RECTANGULAR/SQUARE
RECTANGULAR FLUSH MTG
Cross Reference | NSN 6625-01-329-4423
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 214A-24VDC | 02708 | AGE LOGISTICS CORPORATION |
| 214-24VDC | 02708 | AGE LOGISTICS CORPORATION |
| 214A-24VDC | 00994 | COLUMBUS JACK CORPORATION |
| 214L-24VDC | 31358 | FLIGHT SYSTEMS, INC. |
| 214A-24VDC | 31358 | FLIGHT SYSTEMS, INC. |
| 204-24VDC | 31358 | FLIGHT SYSTEMS, INC. |
Technical Data | NSN 6625-01-329-4423
| Characteristic | Specifications |
|---|---|
| INSTALLATION DESIGN | PANEL |
| PANEL FOR WHICH DESIGNED | NONMAGNETIC |
| INDICATOR TYPE | DIAL W/POINTER |
| SCALE MARKING | PERCENT BATTERY ENERGY; 0 TO 100 |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD AND 2 WIRE LEAD |
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
| OPERATING VOLTAGE RATING IN VOLTS | 24.0 DC NOMINAL |
| STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.062 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 3.500 INCHES NOMINAL |
| OVERALL HEIGHT | 2.375 INCHES NOMINAL |
| OVERALL LENGTH | 4.125 INCHES NOMINAL |
| OVERALL WIDTH | 2.375 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| MOUNTING HOLE DIAMETER | 0.138 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.875 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.879 INCHES NOMINAL |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
| SPECIAL FEATURES | 100 PCT INDICATION EQUALS 2.08 V/CELL |
| FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |