NSN 6625-01-330-2744

Part Details | RADIO TEST SET

6625-01-330-2744 A test set primarily designed for use in making examinations of radio equipment. See also TEST SET, ELECTRON TUBE; MULTIMETER; OSCILLOSCOPE; GENERATOR, SIGNAL; and TEST SET, AMPLIFIER.

Alternate Parts: 332.0015.53, SMFP 2, 6625-01-330-2744, 01-330-2744, 6625013302744, 013302744

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66NOV 30, 199001-330-274403662 ( TEST SET, RADIO )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-330-2744
Part Number Cage Code Manufacturer
332.0015.5382199ROHDE & SCHWARZ USA, INC.
SMFP 282199ROHDE & SCHWARZ USA, INC.
Technical Data | NSN 6625-01-330-2744
Characteristic Specifications
TEST TYPE FOR WHICH DESIGNEDFAULT ISOLATE MOBILE TELEPHONE BASE STATION
INCLOSURE FEATURE SINGLE ITEM W/HOUSING
SPECIAL FEATURESRECEIVER MEASUREMENT: TEST SIGNALSIGNAL GENERATOR FREQ RANGE 0.4-520 MHZ,OUTPUT - CW/FM MINUS 137-PLUS 13DBM,AM - MINUS 137-PLUS 7 DBM; OUTPUT IMPEDANCE 50 OHMS VSWR PORM 1.2; AF SYNTHESIZER/SELECTIVE CALL ENCODER: FREQ RANGE - 10 HZ-25 KHZ; OUTPUT VOLTAGE: 0.1 MV-5 V; AMPLITUDE MODULATION: FREQ:50 HZ-20 KHZ INTERNAL,50 HZ-5KHZ EXTERNAL; FREQ MODULATION: 20 HZ-20 KHZ; INTERNAL VOLTAGE (RMS) AT FM EXT 1V PORM 1 PCT; PHASE MODULATION: FREQ 100 HZTO 6 KHZ; AF FREQ METER,AF LEVEL METER,DISTORTION METER,SINAD-RATIO METER,S/N METER,RF FREQ METER,POWER METER,FREQ DEVIATION METER,PHASE DEVIATION METER,MODULATION DEPTH METER,DC VOLTMETER,DC AMMETER; MANUAL,AUTOMATIC; SELF-CONTAINED; IEC-BUS COMPATIBLE;7 FIXED FREQ; NON-VOLATILE MEMORY; CRYSTAL OSCILLATOR; DIGITAL DISPLAY: 6 LCD QUASI-ANALOG