NSN 6625-01-380-3148
Part Details | FAULT LOCATING INDICATOR
6625-01-380-3148 An electrically activated item specifically designed to indicate the occurrence of a malfunction in a component of an electronic set, central or system. It may indicate the malfunction by a pop-out button (e.g. ground fault interrupt outlets) or color change by emitted light or displayed in a window. The indicator may utilize a "push to test" button. It does not make quantitative or qualitative tests such a provided by test sets.
Alternate Parts: BHGD27T12WBLKS597, BHGD27T-12-W/BLK-S597, 6625-01-380-3148, 01-380-3148, 6625013803148, 013803148
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | DEC 01, 2005 | 01-380-3148 | 60639 ( INDICATOR, FAULT LOCATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-380-3148
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| BHGD27T-12-W/BLK-S597 | 10236 | ELECTRODYNAMICS, INC.DBA L-3 COMMUNICATIONS |
Technical Data | NSN 6625-01-380-3148
| Characteristic | Specifications |
|---|---|
| CASE MATERIAL | ALUMINUM |
| FSC APPLICATION DATA | TEST SET, ELECT. EQUIP |
| ELECTRICAL CONNECTION QUANTITY | 2 |
| PRESENTATION TYPE | INDICATOR LIGHT |
| CONTACT QUANTITY | 2 |
| LENGTH | 0.275 INCHES MAXIMUM |
| WIDTH | 0.330 INCHES NOMINAL |
| FEATURES PROVIDED | ENCAPSULATED |
| SPECIAL FEATURES | LAMP SOCKET INCLUDED |
| SPECIAL TEST FEATURES | COLORS IAW FED-STD-595 |
| SUPPLEMENTARY FEATURES | PULSE POWER REQUIRED 650 MW MINIMUM; INSULATION RESISTANCE 100 MEGOHM |