NSN 6625-01-397-1718
Part Details | SIGNAL GENERATOR
6625-01-397-1718 An instrument which produces a continuous audio and/or radio frequency voltage, and which is designed for test purposes only. It may provide an output at one or more fixed frequencies or be continuously variable over one or more bands. The fixed frequency type is distinguished from CALIBRATOR, FREQUENCY in that it is a voltage source and is not primarily intended for checking frequencies from other sources. Excludes GENERATOR, INTERFERENCE.
Alternate Parts: 910218, 910/2-18, 6625-01-397-1718, 01-397-1718, 6625013971718, 013971718
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | OCT 04, 1994 | 01-397-1718 | 03901 ( GENERATOR, SIGNAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-397-1718
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 910/2-18 | 58900 | GIGA-TRONICS INCORPORATEDDBA GIGA-TRONICS |
Technical Data | NSN 6625-01-397-1718
| Characteristic | Specifications |
|---|---|
| FREQUENCY RANGE RATING | +2.000 TO +18.000 GIGAHERTZ |
| FREQUENCY BAND QUANTITY | 4 |
| MODULATOR LOCATION | ANY ACCEPTABLE |
| MODULATION TYPE | W ANY ACCEPTABLE AND SQUARE WAVE |
| PULSE REPETITION FREQUENCY RATING | 100.0 HERTZ MINIMUM AND 50.0 KILOHERTZ MAXIMUM |
| MODULATION DEGREE | AGHB0.1 USEC PULSE AND AGHC10.0 USEC PULSE |
| CURRENT TYPE | AC |
| VOLTAGE RATING | 110.0 VOLTS NOMINAL AND 240.0 VOLTS NOMINAL |
| FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM |
| PHASE | SINGLE |
| INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
| MOUNTING TYPE | TABLE |
| ACCESSORY COMPONENT QUANTITY | 3 |
| ACCESSORY CONTROLLING AGENCY | GIGA-TRONICS |
| ACCESSORY COMPONENT NAME | OPERATION AND MAINTENANCE MANUAL, EXTENDER BOARD SERVICE KIT, POWER CORD |
| SPECIAL FEATURES | LEVELED OUTPUT: 0 TO -99DBM, BAND 1; +5 TO -15DBM, BAND 2; -3 TO -15 DBM, BAND 3; -10 TO -15 DBM, BAND 4; RESOLUTION: 0.1 DBM; ACCURACY: PORM 1DB (.01 TO 18GHZ); DIGITAL SWEEP FUNCTION-AUTO RECYCLE, SINGLE SWEEP AND SINGLE STEP; SWEEP TIME: VARIABLE FROM 10 MSEC TO 100 SEC.; SWEEP TRIGGER INPUT: TTL LOW TO INITIATE SINGLE SWEEP OR STEP; ANALOG SWEEP LENGTH: 1 MHZ TO FULL RANGE; ACCURACY: PORM 5 MHZ; LINEARITY: PORM 10 MHZ; 5 MARKERS; RESOLUTION: 2 MHZ ET/GT 300 MHZ, 75 KHZ LT 300 MHZ, MINIMUM SWEEP TIME: 10 MSEC/BAND, NOMINAL 0.01/26.5 GHZ |
| END ITEM IDENTIFICATION | TESTING OF AN/ALQ-172 SYSTEM |
| USAGE DESIGN | PHASED ARRAY ANTENNA TEST FIXTURE |
| FUNCTIONAL DESCRIPTION | PULSE/FREQ. MOD./DIGITAL SWEEP |