NSN 6625-01-426-1554
Part Details | INSULATION BREAKDOWN TEST SET
6625-01-426-1554 A test set primarily designed to detect and indicate insulation breakdown in electric motors, transformers, and the like, at specific test voltages. See also TEST SET, ARMATURE; and OHMMETER.
Alternate Parts: 3565D, 3560D, 6625-01-426-1554, 01-426-1554, 6625014261554, 014261554
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | MAR 05, 1996 | 01-426-1554 | 16408 ( TEST SET, INSULATION BREAKDOWN ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-426-1554
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 3565D | 04237 | ASSOCIATED RESEARCH INCORPORATED |
| 3560D | 04237 | ASSOCIATED RESEARCH INCORPORATED |
Technical Data | NSN 6625-01-426-1554
| Characteristic | Specifications |
|---|---|
| OUTPUT CURRENT TYPE | AC AND DC |
| OUTPUT VOLTAGE RATING | 5.000 KILOVOLTS MAXIMUM AND 6.000 KILOVOLTS MAXIMUM |
| OUTPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| OUTPUT CURRENT RATING | 12.000 MILLIAMPERES MAXIMUM AND 5.000 MILLIAMPERES MAXIMUM |
| INSTALLATION DESIGN | Q$Z |
| LEAKAGE INDICATOR TYPE | METER |
| METER QUANTITY | 2 |
| METER TYPE | AMMETER AND VOLTMETER |
| SCALE RANGE | +0.0 TO +12.0 MILLIAMPS AND +0.0 TO +6.0 KILOVOLTS |
| TEST LEAD QUANTITY | 2 |
| WIRE LEAD LENGTH | 60.000 INCHES NOMINAL |
| WIRE TERMINATION TYPE | CLIP |
| AC VOLTAGE RATING | A115.0$A230.0 |
| FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM |
| PHASE | SINGLE |
| INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
| OVERALL DEPTH | 14.560 INCHES NOMINAL |
| OVERALL WIDTH | 11.000 INCHES NOMINAL |
| OVERALL HEIGHT | 3.500 INCHES NOMINAL |
| CIRCUIT OVERLOAD PROTECTION DEVICE | FUSE |
| SPECIAL FEATURES | HY-POT TESTER;T.O.33A1-4-95-1/-11 |
| END ITEM IDENTIFICATION | COMMON TEST EQUIPMENT |