NSN 6625-01-451-0040
Part Details | ELECTRICAL CABLE TEST SET
6625-01-451-0040 A test set primarily designed for use in making examinations of electrical cables. Can be used for locating shorts, crosses, and grounds in electrical cables. This would also permit locating high resistant faults. See also TEST SET (1), POWER-SPECIAL PURPOSE ELECTRICAL CABLE ASSEMBLY. Excludes REFLECTOMETER, METALLIC TIME DOMAIN.
Alternate Parts: 2273U3P3, 2273-U3P3, 2273U3P3, 2273-U3P3, 2273U3P3, 2273-U3P3, 6625-01-451-0040, 01-451-0040, 6625014510040, 014510040
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | DEC 02, 1997 | 01-451-0040 | 03633 ( TEST SET, ELECTRICAL CABLE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-451-0040
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 2273-U3P3 | 53387 | 3M COMPANYDIV ELECTRO AND COMMUNICATIONS |
| 2273-U3P3 | 1DY18 | COLCOM INC |
| 2273-U3P3 | 75037 | MINNESOTA MINING AND MFG CO 3MCOMPANY |
Technical Data | NSN 6625-01-451-0040
| Characteristic | Specifications |
|---|---|
| TEST TYPE FOR WHICH DESIGNED | CABLE AND FAULT LOCATING |
| INTERNAL BATTERY ACCOMMODATION | B |
| INCLOSURE FEATURE | MULTIPLE ITEM W/HOUSING |
| MAJOR COMPONENTS | TRANSMITTER;RECEIVER;EARTH CONTACT FRAME |
| SPECIAL FEATURES | REQUESTED NAME FAULT LOCATOR;RECEIVER DEPTH RANGE 0 TO 15 FT.;RECEIVER REQUIRES SIX ALKALINE "AA" CELLS;TRANSMITTER REQUIRES SIX ALKALINE "C" CELLS;OPTION U3P3 IDENTIFIES USA/CANADA, 10 FT. CABLE W/LARGE ALLIGATOR DIRECT CONNECTION CLIPS, 3 IN. COUPLER KIT |
| FUNCTIONAL DESCRIPTION | LOCATES FAULTS AND TRACES PATHS OF COPPER AND FIBER OPTIC GROUND CABLES |