NSN 6625-01-471-2128

Part Details | OSCILLOSCOPE

6625-01-471-2128 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.

Alternate Parts: TDS784D OPTION 05, TDS784D OPTION 05, 6625-01-471-2128, 01-471-2128, 6625014712128, 014712128

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 26, 200001-471-212800357 ( OSCILLOSCOPE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-471-2128
Part Number Cage Code Manufacturer
TDS784D OPTION 05K3976TEKTRONIX UK LTD
TDS784D OPTION 0580009TEKTRONIX, INC.DBA TEKTRONIX
Technical Data | NSN 6625-01-471-2128
Characteristic Specifications
SWEEP CIRCUITS NOT INCLUDED
AMPLIFIER DEFLECTION SENSITIVITY PROVISION NOT PROVIDED
INPUT INTENSITY MODULATION FEATURE NOT PROVIDED
PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION NOT PROVIDED
FREQUENCY RESPONSE RATING NOT PROVIDED
AMPLIFIER INPUT IMPEDANCE RATING PROVISION PROVIDED
CALIBRATED SCREEN SCALE NOT INCLUDED
TRACE STORAGE TUBE NOT INCLUDED
CAMERA RECORDING DEVICE ACCOMMODATION NOT PROVIDED
CURRENT TYPEB$C
FREQUENCY RATING1.0 GIGAHERTZ NOMINAL
OVERALL WIDTH17.500 INCHES NOMINAL
OVERALL HEIGHT7.600 INCHES NOMINAL
OVERALL DEPTH17.100 INCHES NOMINAL
SPECIAL FEATURESVIDEO TRIGGER NTSC, PAL, HDTV, FLEXFORMAT; 4 CHANNELS
PART NAME ASSIGNED BY CONTROLLING AGENCYDIGITAL PHOSPHOR OSCILLOSCOPE