NSN 6625-01-516-5524

Part Details | TELECOMMUNICATION SYSTEM TEST SET

6625-01-516-5524 A test set designed for use in examining a telecommunication system or subsystem, and providing discreet evaluation of its performance. Its testing capabilities are multiapplication and not limited to measuring single performance characteristics. provides the facilities for voice-grade, program and/or data line testing.

Alternate Parts: D8639, D-8639, 6625-01-516-5524, 01-516-5524, 6625015165524, 015165524

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 09, 200401-516-552437470 ( TEST SET, TELECOMMUNICATION SYSTEM )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-516-5524
Part Number Cage Code Manufacturer
D-863933592MITEQ, INC
Technical Data | NSN 6625-01-516-5524
Characteristic Specifications
TEST TYPE FOR WHICH DESIGNEDFREQUENCY TRANSLATION FOR SATELLITE COMMUNICATIONS
AC VOLTAGE RATINGV250.0
FREQUENCY RATINGE47.0 AND E63.0
INCLOSURE FEATURE SINGLE ITEM W/HOUSING
HEIGHT3.500 INCHES NOMINAL
LENGTH20.000 INCHES MAXIMUM
WIDTH19.000 INCHES NOMINAL
SPECIAL FEATURESBAND 1 RF INPUT 5.85-6.425 GHZ, LO FREQUENCY 2.225 GHZ; RF OUTPUT 3.625-4.2 GHZ; BAND 2 RF INPUT 6.425-6.725 GHZ, LO FREQUENCY 3.025 GHZ, RF OUTPUT 3.4-3.7 GHZ; VOLTAGE 100, 120, 220, 230/240 VAC PORM 10 PCT, -13 PCT, REAR PANEL SELECTABLE, 250 VAC MAX; FREQUENCY 47-63 HZ; POWER CONSUMPTION 120 W TYPICAL; CONNECTORS RF N FEMALE, FRONT PANEL, REAR PANEL WITH OPTION 10; EXTERNAL REFERENCE INPUT, OPTION 6, BNC FEMALE, REAR PANEL; SUMMARY ALARM DE-9P, REAR PANEL; REMOTE INTERFACE, REAR PANEL, DE-9S FOR RS485 AND RS422, DB-25P FOR RS232, DB25S FOR CONTACT CLOSURE, IEEE-488 RECEPTACLE FOR GPIB, EXTERNAL LOCAL OSCILLATOR INPUT, OPTION 4 SMA FEMALE, REAR PANEL; TEST POINTS, FRONT PANEL DC VOLTAGE DISPLAY, LO PHASE VOLTAGE DISPLAY, LO FREQUENCY/POWER MONITOR SMA FEMALE
SUPPLEMENTARY FEATURESENVIRONMENTAL OPEATING AMBIENT TEMPERATURE 0-50 DEG C, RELATIVE HUMIDITY UP TO 95 PCT AT 30 DEG C, ATMOSPHERIC PRESSURE UP TO 10,000 FEET; NONOPERATING AMBIENT TEMP M50-70 DEG C, RELATIVE HUMIDITY UP TO 95 PCT AT 40 DEG C, ATMOSPHERIC PRESSURE UP TO 40,000 FEET, SHOCK AND VIBRATION NORMAL HANDLING BY COMMERCIAL CARRIERS
FUNCTIONAL DESCRIPTIONCONVERSION LOSS 15 DB, 18 DB WITH OPTIONS 1 OR 2; AMPLITUDE RESPONSE PORM 0.25 DB OVER ANY 40 MHZ, PORM 1 DB OVER OUTPUT FREQUENCY BAND; INPUT/OUTPUT RETURN LOSS 20 DB MIN; LEVEL CONTROL 30 DB, 0.2 DB STEP SIZE; INTERMODULATION DISTORTION WITH TWO INBAND SIGNALS AT M13 DBM INPUT, THRID ORDER INTERMODULATION PRODUCTS ARE LESS THAN 50 DBC; INPUT/OUTPUT ISOLATION 60 DB MIN