NSN 6625-01-559-0159

Part Details | FAULT LOCATING INDICATOR

6625-01-559-0159 An electrically activated item specifically designed to indicate the occurrence of a malfunction in a component of an electronic set, central or system. It may indicate the malfunction by a pop-out button (e.g. ground fault interrupt outlets) or color change by emitted light or displayed in a window. The indicator may utilize a "push to test" button. It does not make quantitative or qualitative tests such a provided by test sets.

Alternate Parts: BHGD21T12RBLK, BHGD21T12R-BLK, 9550149580, 6625-01-559-0159, 01-559-0159, 6625015590159, 015590159

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66DEC 03, 200701-559-015960639 ( INDICATOR, FAULT LOCATING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-01-559-0159
Part Number Cage Code Manufacturer
BHGD21T12R-BLK10236ELECTRODYNAMICS, INC.DBA L-3 COMMUNICATIONS
9550149580F0228SAFRAN HELICOPTER ENGINES
Technical Data | NSN 6625-01-559-0159
Characteristic Specifications
CASE MATERIAL ALUMINUM
SPECIAL FEATURESDUAL COIL. DISPLAY BALL CHANGES COLOR ONLY WHEN THE INDICATOR COIL IS PULSED BY BUILT IN TEST EQUIPMENT. NOMINAL D.C VOLTAGE 1.5 TO 28.0. NOMINAL PULSE POWER 650 MILIWATTS. BLACK ANODIZED WITH SEALED GLASS WINDOW. MOUNTING FRONT/BACK AND REAR PANEL THREADED W/ PRESS FIT SLEEVE