NSN 6680-00-068-0302
Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-00-068-0302 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: FS81124, FS8112-4, 6680-00-068-0302, 00-068-0302, 6680000680302, 000680302
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | JAN 01, 1963 | 00-068-0302 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-00-068-0302
Part Number | Cage Code | Manufacturer |
---|---|---|
FS8112-4 | 04577 | CARLETON TECHNOLOGIES INC |
Technical Data | NSN 6680-00-068-0302
Characteristic | Specifications |
---|---|
MEDIA FOR WHICH DESIGNED | B$DBD |
PRESSURE TYPE | MEDIUM |
MAXIMUM DIFFERENTIAL PRESSURE | 15.0 PSI |
SCALE PRESENTATION RANGE | MINUS 10 TO 0 TO PLUS 15 RANGE OF NUMERICAL MARKINGS |
SMALLEST INCREMENT INDICATED | 0.200 |
SCALE INSCRIPTION/BACKGROUND COLOR | WHITE MARKINGS ON BLACK BACKGROUND |
TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
CASE MATERIAL | ALUMINUM |
CASE SHAPE | RECTANGULAR |
MOUNTING TYPE | D ANY ACCEPTABLE |
DEPTH | 8.688 INCHES NOMINAL |
HEIGHT | 6.500 INCHES NOMINAL |
WIDTH | 7.625 INCHES NOMINAL |
INLET CONNECTION SIZE | 1/2 IN.-14 THD NPT |
OUTLET CONNECTION SIZE | 1/4 IN.-18 THD NPT |